| Tutorial 10B.2 - Basic Drawing On the Fly - Video |
|
QuickBuild
Icon |
|
1. "Hydraulic Snap" Set ON !! (located on StatusBar) to force a solid Network connection.
With it Set OFF, it may NOT connect to a valid Network Object 2. Also on the StatusBar, until you become more familiar with modeling in HydrauliCAD, the Hyd. Auto. Calc. is best left as "NON Auto" When active, this feature causes Automatic Network Runs as connections are made, and identifies a Network problem as it occurs. |
|
Click to Place a Junction Node, continue to Click to place Junctions QuickBuild's
natural inclination is to: |
|
To "Cut
Into" an Existing Pipe, and make a solid Network Connection Junction A Message Box appears
YES to Cut
Into Network NOTE: If "NO", Be Cautious in placing an unconnected node near a Network Object as it may appear to be connected and serve to confuse in future |
|
Following a Sequence, it is good practice to Run Analysis often to confirm Network is intact. Then, if there is a Network connection problem, it will be spotted quickly and corrected or one can back up and redo the small section of work. Blue Water Drop on right end of status Bar (see above) confirms a Successful Run & that Network is Intact |
![]() |